Spirax Sarco DEP4 Cast Steel Relief Valve

Chinese yuan (¥) - CNY
  • Chinese yuan (¥) - CNY
  • United States dollar ($) - USD
  • Russian ruble (₽) - RUB

Brand authorization

  • 复选标记 Rapid response service
  • 复选标记 Professional team support
  • 复选标记 Flexible return and exchange policy

Spirax Sarco Spirax Sarco DEP4 cast steel relief valves are cast steel body direct acting bellows sealed relief valves. The standard version has an EPDM diaphragm (max. operating temperature 125°C) and is suitable for water and steam systems. Nitrile rubber diaphragms (suffix "N", maximum operating temperature 90°C) are also available for oil systems. Note: In steam systems, a WS4 water seal tank must be used on the upstream pressure sensing tube to protect the actuator diaphragm, see TI-S12-03.

(an official) standard

The products are fully compliant with the European Pressure Equipment Directive 97 / 23 / EC, with marking on request.

Certification

As standard, products are supplied with manufacturer's typical test certificates. EN 10204 3.1 certificates are available on request. Note: The required certificates and test requirements need to be specified when placing the order.

Available Models

DN15-DN100 flange connection, 6 pressure ranges (suffix 1-6).

Upstream pressure range

realm Valve Model Actuator Model Spring Color DN15 - DN40 pressure range (bar) DN50 - DN80 pressure range (bar) DN100 pressure range (bar) PN Rating
1 DEP4B1 11 or 11N pornographic 0.1 - 0.5 0.1 - 0.3 0.1 - 0.3 2.5
2 DEP4B2 12 or 12N pornographic 0.2 - 0.8 0.2 - 0.5 0.2 - 0.5 2.5
3 DEP4B3 13 or 13N indigo plant 0.5 - 1.7 0.4 - 1.3 0.4 - 1.0 6
4 DEP4B4 14 or 14N indigo plant 1.4 - 3.4 1.0 - 2.6 0.8 - 2.5 16
5 DEP4B5 15 or 15N indigo plant 3.2 - 7.5 2.3 - 5.5 2.3 - 5.0 25
6 DEP4B6 15 or 15N bonus 7.0 - 16.0 5.0 - 15.0 4.0 - 10.0 25

Sizes and pipe connections

DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80 and DN100 flanges: EN 1092 PN40. On request: JIS and ANSI 150, ANSI 300 flanges.

Pressure/Temperature Limits

ontology PN40
PMA Maximum Allowable Pressure 40 bar g @ 50°C
TMA Maximum Allowable Temperature 300°C @ 25.8 bar g
Minimum design temperature 0°C
TMO EPDM Diaphragm Maximum Operating Temperature 125°C
Nitrile rubber diaphragm maximum working temperature 90°C
Minimum operating temperature (ambient) 0°C
PMX Maximum Working Differential Pressure DN15 - DN50 25 bar; DN65 - DN100 20 bar
Design maximum cold hydraulic test pressure 60 bar g
classifier for sums of money The test pressure should not exceed 40 bar g after installation of the internal components.

Kvs value

Caliber DN 15 20 25 32 40 50 65 80 100
Kvs 3.4 6.5 11.4 16.4 24 40 58 92 145

Note: The above KVS value is the value when the valve is fully open and is used for safety valve selection.

material (that sth is made of)

Item Part material (that sth is made of)
1 valve body Cast steel GP 240 GH
2 bonnet Cast steel DIN 17245 GSC25
3 Seat Stainless steel BS 970 431 S29
4 Seat gasket DN15: stainless steel; DN20 and DN25: mild steel; DN32 - DN50: reinforced flake graphite
5 spool Stainless steel BS 970 431 S29
6 Spool Bolt DN15 and DN20: stainless steel BS 6105 A2
7 Spool Seal DN15 and DN20: Arlon 1555
8 bushing Stainless steel BS 970 431 S29
11 Balanced Bellows Assembly Gasket DN25 - DN100: Reinforced flake graphite
12 Cap Gasket Reinforced flake graphite
13 Bonnet bolts DN15 - DN40 M10: Steel DIN 267 Pt13 Gr. 8
14 DN50 and DN65 M12: steel DIN 267 Pt13 Gr. 8.8; DN80 and DN100 M16
15 mainstay Galvanized steel BS 970 230 M07
16 Pillar Nuts Galvanized steel BS 3693 Gr. 8
17 Spring Adjuster Galvanized cast iron DIN 1691 GG25
18 sprung chrome-vanadium steel
19 Bearing (part of component 20) PTFE / steel composite
20 Sealed Bellows Assemblies Stainless steel AISI 316L
21 Sealing Bellows Gasket DN15 and DN20: stainless steel 'S' type; DN25 - DN100: reinforced flake graphite
22 fixing nut DN25 - DN100: galvanized steel BS 970 230 M07
25 locknut Galvanized steel BS 970 230 M07
26 spring-loaded stopper Galvanized steel BS 1449 Pt 1 HR14
27 needle roller bearing steel (chemistry)
28 Setting Nut Galvanized steel BS 970 230 M07
29 Bearing Locator Galvanized steel BS 970 230 M07
30 Regulator Sleeve galvanized steel
31 Mounting Stalls Types 11(N) - 14(N): Galvanized steel BS 1449 Pt 1 HR14 DIN 1514 St W24
32 housings Type 15(N): Steel BS EN 10025 S355 J2G3
33 Housing bolts Types 11(N) - 12(N): galvanized steel BS 3692 Gr. 5.6; Types 13(N), 14(N) and 15(N): galvanized steel BS 3692 Gr. 8.8
34 Housing Nut Types 11(N) and 12(N): galvanized steel BS 3692 Gr. 5.6; Types 13(N), 14(N) and 15(N): galvanized steel BS 3692 Gr. 8
35 crown bar guide Stainless steel BS 970 431 S29
36 diaphragm EPDM or Nitrile Rubber
37 hexagonal screw Stainless steel BS 6105 A2
38 sealing gasket fibroid
39 diaphragm clamp Stainless Steel ASTM A351 CF8M
40 pistons Galvanized carbon steel BS 1449 Pt 1 HR14
41 top bar Galvanized carbon steel BS 970 230 M07
42 mounting nut Galvanized steel BS 3692 Gr. 8
43 pipe fitting galvanized steel
44 Threaded Inserts DN15 and DN20: stainless steel DTD 734; DN25 - DN100: galvanized steel BS 1449 CR4
45 Self-locking nuts Galvanized steel BS 1449 CR4
46 spread litter in a cowshed, pigsty etc Type 12(N) only: galvanized steel
47 spring ring galvanized steel
48 Top Rod Seal 'O' Ring EPDM or Nitrile Rubber
49 bear the weight of (a building) PTFE/steel composite
50 Housing seal 'O' ring EPDM or Nitrile Rubber
51 bleeder plug plastics
52 coupling clip Galvanized steel ASTM A216 Gr. WCB
53 sprung Spring steel BS 5216 Gr. M4
54 set screw Galvanized steel BS 4168 Gr. 12.9
55 retaining plate DN65 to DN100 only: Stainless steel ASTM A276 316L
56 Sealing Gasket Reinforced flake graphite

Sizing for Steam Applications

Use the selection table to determine the valve Kv for steam applications through; - upstream pressure - maximum valve pressure drop - maximum steam load. Knowing the valve Kv, the valve pressure drop at any given flow rate can be determined.

Selection of water applications

Use the selection table to determine the valve Kv for steam applications through; - Maximum flow rate - Maximum valve pressure drop. Knowing the valve Kv, the valve pressure drop at any given flow rate can be determined.

Spare Parts

Spare parts available (DN15 to DN20)

connection A
Diaphragm assemblies (diaphragms and gaskets) B, C
needle roller bearing D
Sealed Bellows Assemblies Seal bellows, bellows gasket, bonnet gasket: E, F, G, H
Control springs I
Seat/spool assembly Seats, seat gaskets, spool and bonnet gaskets: J, K, L, G, H
Gasket set Sealing bellows gaskets, bonnet gaskets, and seat gaskets: F, G, K
Actuator rod guide set Shaft guides, bearing bushings, shaft sealing 'O' rings, cavity sealing 'O' rings and retaining rings: P, R, S, T, V

Spare parts available (DN25 to DN100)

connection
Diaphragm assemblies (diaphragms and gaskets)
needle roller bearing
Sealed Bellows Assemblies
Control springs
DN25-DN50 seat/spool assemblies
DN65-DN100 spool assemblies
DN25-DN50 balanced bellows assembly
DN65-DN100 balanced bellows assembly
DN25-DN50 gasket set
DN65-DN100 gasket set
Actuator Bearing Assembly

Ordering Spare Parts Order spare parts according to the instructions above, specifying the valve size and model number. Example: 1-gasket set for DN 25 DEP4B1 relief valve.

mounting

Detailed installation instructions are provided in the installation and maintenance guide supplied with the spare part.

weights

Valve weight (kg)

Valve Caliber DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100
Yellow spring weight 11.6 13.3 16.7 21.4 23.7 26.3 37.7 46.0 69.8
Blue Spring Weight 11.6 13.3 16.7 21.4 23.7 26.3 37.7 46.0 69.8
Red spring weight 13.6 14.8 18.2 22.9 25.2 27.8 39.4 47.7 72.5

Actuator weight (kg)

Actuator Model 1 or 1N 2 or 2N 3 or 3N 4 or 4N 5 or 5N
weights 12.3 6.5 4.0 2.6 2.7

Note: Total product weight equals the weight of the valve and actuator combined.

Security information, installation and maintenance

See the Installation and Maintenance Guide supplied with the product for detailed information. (IM-S12-10)

NOTE: When applied to steam systems, to protect the actuator diaphragm, a WS4 water seal tank should be installed upstream and connected to the actuator by a sensing tube. See TI-S12-03 for details.This valve should be installed vertically downstream in horizontal piping, ensuring that the direction of flow is as indicated by the arrow on the valve body. The valve can also be installed vertically upwards when the upstream temperature is below 125°C.

Order Installation

Example: 1 - Spirax Sarco DN40 DEP4B3 direct acting relief valve, Flanged, PN40. Note: Add suffix 'N' if Buna N diaphragm is required, also DEP4 B3N.

Spirax Sarco Spirax Sarco DEP4 Cast Steel Relief Valve Structural Drawing

 

Technical Data Download